MULTIMATIC change-over regulator system incl. test valve and safety relief valve for the operation of two gas cylinders with automatic change-over.
Technical data:
Outlet pressure: 50 mbarFlow rate: 1.5 kg/hRegulator inlet: External thread M 20 x 1.5Regulator outlet: 8 mm pipeworkApproval: Europe-wide approval according to standard 13786Weight: 1.93 kg
Switchover:
The automatic switchover from the operating cylinder to the reserve cylinder takes place without interrupting the gas supply. The "switchover arrow"(green = operation, red = reserve or empty) indicates which cylinder is in operation or empty.
Installation:
The MULTIMATIK is mounted on the wall of the gas locker. The compact design means that it can also be installed where space is limited. A mounting plate fitted to the changeover unit enables safe, quick and easy installation.
Cylinder connection:
The two high-pressure hoses included in the scope of delivery can be connected to all commercially available 3, 5, 11 and 33 kg gas cylinders with KLF (small cylinder connection), G.5, G.12 valve connection.
Scope of delivery:
1 x 50 mbar / 1.5 kg/h lpg regulator with automatic 2-bottle switchover and test valve2 x 450 mm high-pressure hoses including hose rupture protection
Safety instructions and warnings
Safety instructions for 2 gas cylinders automatic changeover unit MULTIMATIK 50 mbar incl. 2 high-pressure hoses
- Follow the manufacturer's operating instructions and strictly adhere to the instructions contained therein. - Ensure that the gas cylinders are properly connected and that the system is leak-proof before putting it into operation. - Regularly check the condition of the HP hoses for damage or wear. If there are signs of cracks or defects, replace the hoses immediately. - Ensure that the gas cylinders are securely and stably positioned to prevent them from tipping over or falling. - Only use high-pressure hoses that are approved for use with this changeover unit. - Ensure that the changeover unit is installed correctly and that all connections are properly tightened. - Observe the specified gas pressures and ensure that these are not exceeded. - Only use the changeover unit in well-ventilated areas and avoid using it in closed rooms without an adequate supply of fresh air. - Switch off the changeover unit when it is not in operation and close the gas cylinder valves. - Do not use the changeover unit in the vicinity of naked flames or flammable materials. - Observe the national and local regulations and safety regulations for the operation of LPG conversion kits. Please note that this is only a general compilation of safety and operating instructions. For detailed information and specific instructions, please consult the official manufacturer's sources.
Manufacturer contact information
Manufacturer Contact
Cavagna Group
Via Statale n. 11/13
25011 Ponte S. Marco di Calcinato
Brescia - Italy
https://www.cavagnagroup.com/contacts/