2-bottle ALUGAS set with connection for simultaneous refuelling!
Whether in a motorhome, caravan, camper, food truck, boat or road construction, with our fuel gas bottle your gas supply is cheap, safe and sustainably covered!
ALUGASTankflasche, from current production.these gas cylinders are refillable by a gas filling station Europe-wide. The 80% fill stop valve automatically stopsthe refuelling process when each bottle is filled with approx. 26.5L (11KG). In addition, a fill level indicatorattached to each bottle informs you about the current fill level. Refuelling is possible at any time!
The low weight of only 7.5 KG(per bottle) enables easy handling and versatile use, e.g. barbecuing, heating, cooking, etc. The bottle collar can be loosened by two screws.
The refillable gas cylinders are supplied with installation set, connection set for simultaneous filling and all adapters used in Europe. On request, we also offer high-quality stainless steel wall brackets for these bottles. Please refer to the respective offer description for the exact scope of delivery.
Advantages:
- enormously light weight of thecylinder of only 7,5kg
- no need to change cylinders - independent of gas deposit cylinders
- automatic 80% fill stop - no overfilling possible!
- cheap refuelling at more than 30.000 petrol stations all over Europe
- compatible with all gas-powered appliances such as heaters, fridges, cookers, etc.
- can be refuelled at any time
- removable collar
- integrated level indicator on the valve
Scope of delivery:
2x ALUGAS refillable gas cylinder 14KG incl. 80% fill stop valve
1x CAMPKO refuelling valve HK flat 90°angled with filling hose connection
1x DREHMEISTER bracket for filling valve HK flat
1x CAMPKO LPG filling hose 1.00 metre straight - 90° angled (refuelling)
1x CAMPKO LPG filling hose 0.75 metre straight - 90° angled (connection between the two cylinders)
1x DREHMEISTER bayonet LPG gas connector 22mm
1x DREHMEISTER DISH gas connector 22mm
1x DREHMEISTER ACME gas connector 22mm
1x DREHMEISTER Euronozzle tank connector 22mm
1x DREHMEISTER T-piece G 3/4 UNF 2 x external thread 1 x internal thread (branch for 2nd bottle)
1x DREHMEISTER adapter case for ACME, DISH, bayonet, Euronozzle gas connector
Technical specifications (for one bottle):
Water volume 33,3L
Filling weight propane 14.0 kg
Filling weight butane 16,3 kg
Tare weight 7,5 kg
Total height 688mm
Height without collar: 648mm
Diameter 300mm
Gas outlet: G.12 small cylinder connection (KLF)
Approval: CE0036 PED 1997-23EG
QUESTIONS & ANSWERS
What do I have to consider before the first refuelling?
The refillable gas cylinders are tested for leaks at the factory using air pressure. The test pressure is then released. Therefore, the Withdrawal valve (hand wheel) should be opened before refuelling to release residual pressure and then closed again. However, a small amount of residual air remains in the refillable gas cylinder. During the first refuelling, this causes an enormous coldness inside the tank. In exceptional cases, the float of the fill stop valve may ice up and not close in time. Therefore, never fill more than 21.5L into the bottle. Even with a two-bottle system, never refuel more than specified. During the refuelling process, keep an eye on the fuel pump's running gear and stop it manually if necessary.
What are the differences between the bottles you offer?
The most important difference is the material. If weight is not an important factor for you, steel cylinders are the cheapest option for sustainable gas supply. If you absolutely want to get by with less additional weight, you should consider our ALUGAS or composite cylinders. For more details, please refer to the respective product description of the cylinders.
Is a declaration of conformity from ALUGAS supplied?
Yes, a declaration of conformity can be sent as a PDF file on request after purchase.
What happens after 10 years?
After 10 years, the cylinder must be retested or replaced.
Are there cylinders that do not have to be tested after 10 years?
Only cylinders with 67R-01 approval do not have to be subjected to a 10-year test unless the manufacturer stipulates it. This would be the case, for example, with the black steel bottle in our range.
Is the bottle allowed to lie down?
In order to guarantee the function of the 80% fill stop and a gaseous withdrawal, the bottle must be mounted vertically.
How must the bottle be mounted?
If you are using the bottle with an external filling valve, the bottle must be mounted securely in accordance with G607. Please discuss your plans in advance with a specialist workshop, a G607 expert or the responsible testing organisation (TÜV/DEKRA/GTÜ/KÜS etc.).
Do I need an acceptance test?
After the cylinder has been permanently installed, an acceptance test by the responsible testing organisation is required.
Where is the nearest G607 expert in my area?
Depending on the region, we can help you find a G607 expert. Simply send us a message with your postcode using the contact form.
Where can I have the cylinder installed?
The cylinders should be installed by a specialist company. If you wish, we can arrange for the installation company in your area. Simply contact us via the contact form and tell us your postcode.
Can I fill up at any LPG filling station?
Once the installation has been approved, you can fill up at any filling station in Europe.
Which gas can be refuelled?
The so-called bottled gas from the conventional exchange bottles is basically no different from LPG, which you refuel on your own. Both gases are a mixture of propane and butane. Abroad, LPG is also called GLP or GPL.
Why are so many different sets offered?
We try to offer the right set for everyone. Therefore, please note the scope of delivery in the description of the respective set. If you cannot find what you are looking for, please contact us using the contact form. A competent member of staff will help you with your question.
Please note that the above information refers exclusively to the German G607 regulations. Guidelines of other testing organisations or countries could not be considered by us. In any case, please contact your responsible testing organisation.